NXP Amplifiers 1U Architect & Engineering Specs nXp1504 The unit shall be a 4 channel multi-mode amplifier capable of driving 2 Ohm loads at full power. The maximum rated output power shall be 150W per channel at Low Z, 150W per channel in 25V mode, 150W per channel in 70V mode, and 150W per channel in 100V mode. There shall be an automatic but defeatable sleep mode consuming <1W, and instant standby mode controlled by contact closure or software. A switch mode power supply with active power factor correction (PFC) shall auto-detect 100 – 240VAC mains and operate from 70 – 270VAC. Each channel shall have selectable output mode of Low Z, 25V, 70V, or 100V, an 80Hz high-pass filter, input limiter, and input gain settings of 26dB, 32dB, 38dB, or 1.4V. Each channel shall have remote DC level control. Input connectors shall be 3.5mm Euroblock, while output connectors shall be 7.62mm Euroblock. The unit shall have a front panel power switch and rear level controls that can be disabled. LEDs shall indicate Protect, Sleep, Disabled, and Bridge mode status, as well as Temperature, Output Current, Output Signal, and Clipping/Mute status per channel. The unit shall have Ethernet control with a real-time clock for event scheduling. The unit shall have serial data remote control, aux preamp outputs, preset control, and fault condition logic output per channel. The unit shall have optional factory installed network audio or AES3 digital audio capability. The unit shall have 32-bit DSP processing at 48kHz or 96kHz sampling rate. DSP functions shall include swept load impedance, gain, dynamics including autoleveler and ambient noise compensation, equalization including graphic, parametric, feedback suppressor, and FIR filters, a matrix mixer including automixing, crossover, delay, and a signal generator. The amplifier shall have temperature dependent variable speed forced-air cooling. The unit shall weigh <13.1 lbs (5.9kg), measure 19”W x 1.75”H x 14.54”D (483mm x 45mm x 369mm), and mount in a standard 19” rack. The power amplifier shall be an Ashly nXp1504. nXp1502 The unit shall be a 2 channel multi-mode amplifier capable of driving 2 Ohm loads at full power. The maximum rated output power shall be 150W per channel at Low Z, 150W per channel in 25V mode, 150W per channel in 70V mode, and 150W per channel in 100V mode. There shall be an automatic but defeatable sleep mode consuming <1W, and instant standby mode controlled by contact closure or software. A switch mode power supply with active power factor correction (PFC) shall auto-detect 100 – 240VAC mains and operate from 70 – 270VAC. Each channel shall have selectable output mode of Low Z, 25V, 70V, or 100V, an 80Hz high-pass filter, input limiter, and input gain settings of 26dB, 32dB, 38dB, or 1.4V. Each channel shall have remote DC level control. Input connectors shall be 3.5mm Euroblock, while output connectors shall be 7.62mm Euroblock. The unit shall have a front panel power switch and rear level controls that can be disabled. LEDs shall indicate Protect, Sleep, Disabled, and Bridge mode status, as well as Temperature, Output Current, Output Signal, and Clipping/Mute status per channel. The unit shall have Ethernet control with a real-time clock for event scheduling. The unit shall have serial data remote control, aux preamp outputs, preset control, and fault condition logic output per channel. The unit shall have optional factory installed network audio or AES3 digital audio capability. The unit shall have 32-bit DSP processing at 48kHz or 96kHz sampling rate. DSP functions shall include swept load impedance, gain, dynamics including autoleveler and ambient noise compensation, equalization including graphic, parametric, feedback suppressor, and FIR filters, a matrix mixer including automixing, crossover, delay, and a signal generator. The amplifier shall have temperature dependent variable speed forced-air cooling. The unit shall weigh <12.1 lbs (5.5kg), measure 19”W x 1.75”H x 14.54”D (483mm x 45mm x 369mm), and mount in a standard 19” rack. The power amplifier shall be an Ashly nXp1502. nXp754 The unit shall be a 4 channel multi-mode amplifier capable of driving 2 Ohm loads at full power. The maximum rated output power shall be 75W per channel at Low Z, 75W per channel in 25V mode, 75W per channel in 70V mode, and 75W per channel in 100V mode. There shall be an automatic but defeatable sleep mode consuming <1W, and instant standby mode controlled by contact closure or software. A switch mode power supply with active power factor correction (PFC) shall auto-detect 100 – 240VAC mains and operate from 70 – 270VAC. Each channel shall have selectable output mode of Low Z, 25V, 70V, or 100V, an 80Hz high-pass filter, input limiter, and input gain settings of 26dB, 32dB, 38dB, or 1.4V. Each channel shall have remote DC level control. Input connectors shall be 3.5mm Euroblock, while output connectors shall be 7.62mm Euroblock. The unit shall have a front panel power switch and rear level controls that can be disabled. LEDs shall indicate Protect, Sleep, Disabled, and Bridge mode status, as well as Temperature, Output Current, Output Signal, and Clipping/Mute status per channel. The unit shall have Ethernet control with a real-time clock for event scheduling. The unit shall have serial data remote control, aux preamp outputs, preset control, and fault condition logic output per channel. The unit shall have optional factory installed network audio or AES3 digital audio capability. The unit shall have 32-bit DSP processing at 48kHz or 96kHz sampling rate. DSP functions shall include swept load impedance, gain, dynamics including autoleveler and ambient noise compensation, equalization including graphic, parametric, feedback suppressor, and FIR filters, a matrix mixer including automixing, crossover, delay, and a signal generator. The amplifier shall have temperature dependent variable speed forced-air cooling. The unit shall weigh <13.1 lbs (5.9kg), measure 19”W x 1.75”H x 14.54”D (483mm x 45mm x 369mm), and mount in a standard 19” rack. The power amplifier shall be an Ashly nXp754. nXp752 The unit shall be a 2 channel multi-mode amplifier capable of driving 2 Ohm loads at full power. The maximum rated output power shall be 75W per channel at Low Z, 75W per channel in 25V mode, 75W per channel in 70V mode, and 75W per channel in 100V mode. There shall be an automatic but defeatable sleep mode consuming <1W, and instant standby mode controlled by contact closure or software. A switch mode power supply with active power factor correction (PFC) shall auto-detect 100 – 240VAC mains and operate from 70 – 270VAC. Each channel shall have selectable output mode of Low Z, 25V, 70V, or 100V, an 80Hz high-pass filter, input limiter, and input gain settings of 26dB, 32dB, 38dB, or 1.4V. Each channel shall have remote DC level control. Input connectors shall be 3.5mm Euroblock, while output connectors shall be 7.62mm Euroblock. The unit shall have a front panel power switch and rear level controls that can be disabled. LEDs shall indicate Protect, Sleep, Disabled, and Bridge mode status, as well as Temperature, Output Current, Output Signal, and Clipping/Mute status per channel. The unit shall have Ethernet control with a real-time clock for event scheduling. The unit shall have serial data remote control, aux preamp outputs, preset control, and fault condition logic output per channel. The unit shall have optional factory installed network audio or AES3 digital audio capability. The unit shall have 32-bit DSP processing at 48kHz or 96kHz sampling rate. DSP functions shall include swept load impedance, gain, dynamics including autoleveler and ambient noise compensation, equalization including graphic, parametric, feedback suppressor, and FIR filters, a matrix mixer including automixing, crossover, delay, and a signal generator. The amplifier shall have temperature dependent variable speed forced-air cooling. The unit shall weigh <12.1 lbs (5.5kg), measure 19”W x 1.75”H x 14.54”D (483mm x 45mm x 369mm), and mount in a standard 19” rack. The power amplifier shall be an Ashly nXp752.