Ashly AQM1208 AquaControl Firmware Revision History --------------------------------------------------- Version 1.2.1 (Feature & Service Release) 10-21-2026 - Fixed issue where settings could potentially be wiped or out-of-sync if power is interrupted at a very specific time during a parameter change. - Added blocking of triggered events, scheduled events, and network/remote parameter changes during preset recall, import, and firmware update to prevent unintended consequences or the possibility of some features to stop working until power is cycled. - GPI-triggers now respond quicker and an issue was fixed that could cause toggle events to end out-of-sync with the final trigger position when switched back and forth quickly. - Added channel numbers that are independent of the editable channel names on Signal Chain and Mixer pages. - Improved Last Recalled Preset name on the Signal Chain page to set it during full preset saves and make sure it automatically refreshes when events, remotes and other control devices cause preset changes. - Improved preset preview to show missing items, correct some label issues, and fix mixer view. Version 1.2.0 (Feature & Service Release) 07-26-2026 - Added new AquaControl device discovery protocol and Dashboard tab to show Other Devices on the network that support it. - Includes the latest Ethernet security patches for July 2026. Version 1.1.8 (Feature & Service Release) 03-11-2026 - Updated network hostname format to improve DNS compatibility. The new web browser connection format is: aqm1208-(last 6 MAC address characters).local example: aqm1208-036fff.local - Updated Samba SSDP and UPnP device discovery services for compatibility with Windows 11 security changes. - Upgraded DCAs from 4 to 12. - Improved remote screen navigation and added a new home page for remote page selection and sign-out. - Improved client reconnect time, so pages reload quicker after screen time-out, page refresh, updates, etc. - Fixed date/time and time zone manager to fix issues with scheduled events not working properly. - Fixed issue where the PEQ All Pass filter type was not working properly. - Fixed issue where some FIR files with fewer than 512 taps may cause audio glitches. - Fixed ANC selection of noise source inputs 10-12. - Fixed compressor RMS detector selection where it was previously erroneously using a Peak detector type. - Improved firmware update process with progress bar and step status. Version 1.1.1 (Feature & Service Release) 12-10-2024 - Added custom background/foreground images feature to Virtual WR5 remotes. - Improved Virtual WR-5 remote control components, scaling, and selection behavior. - Improved the mixer remote faders to eliminate latency. - Added more Diagnostic page entry types related to DSP status. - Fixed issue where some units may not pass audio when cold booted. - Fixed issue with RTC battery voltage monitoring. - Fixed issue with events where repeat N days field allowed leading zeros that caused events page to not display. - Fixed issue with Virtual WR5 remote nav buttons. Wrong nav buttons were appearing. - Fixed issue with extra log messages being added to diagnostics log (GPO pin toggles). - Fixed issue with special characters in presets and templates causing multiple failures in save / preview / delete / load. - Fixed issue were navigating from DCA or Mixer remotes to a Virtual WR5 remote containing spaces would show a blank screen Version 1.0.6 (Service Release) 05-08-2024 - Revamped all remote pages to improve layout/compatibility with AquaTouch7 remote and mobile devices. - Fixed issue that may cause DCA to stop functioning. Version 1.0.2 (Service Release) 03-16-2024  - Improved feedback suppressor performance and fixed issues with locking filters.  - Fixed issue where deleting compressors or clearing the signal chain can cause audio to stop passing. - Improved VCA response time.  - Improved compare view screens.  - Fixed issue where leading zeros in dates caused an error on the events page. - Fixed a race condition that can prevent the DSP from passing audio after a very brief power interruption. - Fixed an issue that can cause the meters to stop working in the browser. - Fixed an issue where users with the role Operator lose access to a Virtual WR5 remote after it is edited.  Version 0.0.21 (Production Release) 01-08-2024