Ashly AQM408 AquaControl Firmware Revision History -------------------------------------------------- Version 1.2.1 (Feature & Service Release) 11-07-2026 - Fixed issue where settings could potentially be wiped or out-of-sync if power is interrupted at a very specific time during a parameter change. - Added blocking of events and remote parameter changes during preset recall, import, and firmware update, to prevent unintended results or the possibility of some features to stop working until power is cycled. - GPI-triggers now respond quicker and an issue was fixed that could cause toggle events to end out-of-sync with the final trigger position when switched back and forth quickly. - Added channel numbers that are independent of the editable channel names on Signal Chain and Mixer pages. - Improved Last Recalled Preset name on the Signal Chain page to reflect preset saves and refresh when events, remotes and other control devices cause preset changes. - Improved preset preview to show missing items, correct some label issues, and fix mixer view. Version 1.2.0 (Feature & Service Release) 07-26-2026 - Added new AquaControl device discovery protocol and Dashboard tab to show Other Devices on the network that support it. - Includes the latest Ethernet security patches for July 2026. Version 1.1.4 (Service Release) 04-20-2026 - Updated network hostname format to improve DNS compatibility. The new web browser connection format is: aqm408-(last 6 MAC characters).local example: aqm408-036fb1.local - Updated Samba SSDP and UPnP device discovery services for compatibility with Windows 11 security changes. - Improved remote screen navigation and added a new home page for remote page selection and sign-out. - Improved client reconnect time, so pages reload quicker after screen time-out, updates, etc. - Improved firmware update process with progress bar and step status. - Fixed date/time and time zone manager to fix issues with scheduled events not working properly. - Fixed issue where the PEQ All Pass filter type was not working properly. - Fixed compressor RMS detector selection where it was previously erroneously using a Peak detector type. - Fixed Admin reset which restores DHCP settings and the factory default login credentials. - General performance improvements. Version 1.1.2 (Service Release) 04-05-2025 - Fixed issue that may have caused some FIR files to not work. - Fixed Graphic EQ issue where enable status was not being set on power up. Version 1.1.1 (Feature & Service Release) 12-10-2024 - Added custom background/foreground images feature to Virtual WR5 remotes. - Improved Virtual WR-5 remote control components, scaling, and selection behavior. - Improved the mixer remote faders to eliminate latency. - Added more Diagnostic page entry types related to DSP status. - Fixed issue where some units may not pass audio when cold booted. - Fixed issue with RTC battery voltage monitoring. - Fixed issue with events where repeat N days field allowed leading zeros that caused events page to not display. - Fixed issue with Virtual WR5 remote nav buttons. Wrong nav buttons were appearing. - Fixed issue with extra log messages being added to diagnostics log (GPO pin toggles). - Fixed issue with special characters in presets and templates causing multiple failures in save / preview / delete / load. - Fixed issue were navigating from DCA or Mixer remotes to a Virtual WR5 remote containing spaces would show a blank screen Version 1.0.2 (Initial Production Release) 05-25-2024