NXP Amplifiers 2U Architect & Engineering Specs nXp3.04 The unit shall be a 4 channel multi-mode amplifier capable of driving 2 Ohm loads at full power. The maximum rated output power shall be 3,000W per channel at Low Z, 2,450W per channel in 70V mode, and 1,250W in 100V mode. There shall be an automatic but defeatable sleep mode consuming <1W, and instant standby mode controlled by contact closure or software. A switch mode power supply shall auto-detect 110 – 120VAC or 220 – 240VAC mains, and a Neutrik® powerCON shall be used for the AC cord. Each channel shall have selectable output mode of Low Z, 70V, or 100V, an 80Hz high-pass filter, input limiter, and input gain settings of 26dB, 32dB, 38dB, or 1.4V. Each channel shall have remote DC level control. Input connectors shall be Neutrik® XLR/TRS combo jack and Euroblock, while output connectors shall be Neutrik® speakON. The unit shall have a front panel power switch and level controls that can be disabled. LEDs shall indicate Protect, Sleep, Disabled, Com, and Bridge mode status, as well as Temperature, Output Current, Output Signal, and Clipping/Mute status per channel. The unit shall have Ethernet control with a real-time clock for event scheduling. The unit shall have serial data remote control, aux preamp outputs, preset control, fault condition logic outputs, optional network audio and AES3 digital audio capability. The unit shall have 32-bit DSP processing at 48kHz or 96kHz sampling rate. DSP functions shall include swept load impedance, gain, dynamics including autoleveler and ambient noise compensation, equalization including graphic, parametric, feedback suppressor, and FIR filters, a matrix mixer including automixing, crossover, delay, and a signal generator. The amplifier shall have temperature dependent variable speed forced-air cooling. The unit shall weigh <28.7 lbs (13kg), measure 19”W x 3.5”H x 16.8”D (483mm x 89mm x 428mm), and mount in a standard 19” rack. The power amplifier shall be an Ashly nXp3.04. nXp3.02 The unit shall be a 2 channel multi-mode amplifier capable of driving 2 Ohm loads at full power. The maximum rated output power shall be 3,000W per channel at Low Z, 2,450W per channel in 70V mode, and 1,250W in 100V mode. There shall be an automatic but defeatable sleep mode consuming <1W, and instant standby mode controlled by contact closure or software. A switch mode power supply shall auto-detect 110 – 120VAC or 220 – 240VAC mains, and a Neutrik® powerCON shall be used for the AC cord. Each channel shall have selectable output mode of Low Z, 70V, or 100V, an 80Hz high-pass filter, input limiter, and input gain settings of 26dB, 32dB, 38dB, or 1.4V. Each channel shall have remote DC level control. Input connectors shall be Neutrik® XLR/TRS combo jack and Euroblock, while output connectors shall be Neutrik® speakON. The unit shall have a front panel power switch and level controls that can be disabled. LEDs shall indicate Protect, Sleep, Disabled, Com, and Bridge mode status, as well as Temperature, Output Current, Output Signal, and Clipping/Mute status per channel. The unit shall have Ethernet control with a real-time clock for event scheduling. The unit shall have serial data remote control, aux preamp outputs, preset control, fault condition logic outputs, optional network audio and AES3 digital audio capability. The unit shall have 32-bit DSP processing at 48kHz or 96kHz sampling rate. DSP functions shall include swept load impedance, gain, dynamics including autoleveler and ambient noise compensation, equalization including graphic, parametric, feedback suppressor, and FIR filters, a matrix mixer including automixing, crossover, delay, and a signal generator. The amplifier shall have temperature dependent variable speed forced-air cooling. The unit shall weigh <22.7 lbs (10.3kg), measure 19”W x 3.5”H x 16.8”D (483mm x 89mm x 428mm), and mount in a standard 19” rack. The power amplifier shall be an Ashly nXp3.02. nXp1.54 The unit shall be a 4 channel multi-mode amplifier capable of driving 2 Ohm loads at full power. The maximum rated output power shall be 1,500W per channel at Low Z and 70V modes, and 1,250W in 100V mode. There shall be an automatic but defeatable sleep mode consuming <1W, and instant standby mode controlled by contact closure or software. A switch mode power supply shall auto-detect 110 – 120VAC or 220 – 240VAC mains, and a Neutrik® powerCON shall be used for the AC cord. Each channel shall have selectable output mode of Low Z, 70V, or 100V, an 80Hz high-pass filter, input limiter, and input gain settings of 26dB, 32dB, 38dB, or 1.4V. Each channel shall have remote DC level control. Input connectors shall be Neutrik® XLR/TRS combo jack and Euroblock, while output connectors shall be Neutrik® speakON. The unit shall have a front panel power switch and level controls that can be disabled. LEDs shall indicate Protect, Sleep, Disabled, Com, and Bridge mode status, as well as Temperature, Output Current, Output Signal, and Clipping/Mute status per channel. The unit shall have Ethernet control with a real-time clock for event scheduling. The unit shall have serial data remote control, aux preamp outputs, preset control, fault condition logic outputs, optional network audio and AES3 digital audio capability. The unit shall have 32-bit DSP processing at 48kHz or 96kHz sampling rate. DSP functions shall include swept load impedance, gain, dynamics including autoleveler and ambient noise compensation, equalization including graphic, parametric, feedback suppressor, and FIR filters, a matrix mixer including automixing, crossover, delay, and a signal generator. The amplifier shall have temperature dependent variable speed forced-air cooling. The unit shall weigh <28.7 lbs (13kg), measure 19”W x 3.5”H x 16.8”D (483mm x 89mm x 428mm), and mount in a standard 19” rack. The power amplifier shall be an Ashly nXp1.54. nXp1.52 The unit shall be a 2 channel multi-mode amplifier capable of driving 2 Ohm loads at full power. The maximum rated output power shall be 1,500W per channel at Low Z and 70V modes, and 1,250W in 100V mode. There shall be an automatic but defeatable sleep mode consuming <1W, and instant standby mode controlled by contact closure or software. A switch mode power supply shall auto-detect 110 – 120VAC or 220 – 240VAC mains, and a Neutrik® powerCON shall be used for the AC cord. Each channel shall have selectable output mode of Low Z, 70V, or 100V, an 80Hz high-pass filter, input limiter, and input gain settings of 26dB, 32dB, 38dB, or 1.4V. Each channel shall have remote DC level control. Input connectors shall be Neutrik® XLR/TRS combo jack and Euroblock, while output connectors shall be Neutrik® speakON. The unit shall have a front panel power switch and level controls that can be disabled. LEDs shall indicate Protect, Sleep, Disabled, Com, and Bridge mode status, as well as Temperature, Output Current, Output Signal, and Clipping/Mute status per channel. The unit shall have Ethernet control with a real-time clock for event scheduling. The unit shall have serial data remote control, aux preamp outputs, preset control, fault condition logic outputs, optional network audio and AES3 digital audio capability. The unit shall have 32-bit DSP processing at 48kHz or 96kHz sampling rate. DSP functions shall include swept load impedance, gain, dynamics including autoleveler and ambient noise compensation, equalization including graphic, parametric, feedback suppressor, and FIR filters, a matrix mixer including automixing, crossover, delay, and a signal generator. The amplifier shall have temperature dependent variable speed forced-air cooling. The unit shall weigh <22.7 lbs (10.3kg), measure 19”W x 3.5”H x 16.8”D (483mm x 89mm x 428mm), and mount in a standard 19” rack. The power amplifier shall be an Ashly nXp1.52.