TM Series Architect & Engineering Specs TM-335 The unit shall be a three input mixer combined with a 35W amplifier using transformer isolated outputs for Low Z (4 Ohm), 25V, or 70V speakers. There shall be a front panel level control for each Mic input, a master level control, and a master bass and treble control. Input 1 shall be balanced Mic level on Euroblock. Input 2 shall be selectable between balanced Mic level on Euroblock or Stereo Aux input on Euroblock or 3.5mm TRS jack, with TRS input overriding Euroblock. Input 3 shall be selectable between balanced Mic level on Euroblock or stereo CD/Satellite input on RCA jacks. The unit shall have a dedicated balanced Telephone input with gain control. Telephone input shall have ducking priority over all other inputs, with dedicated Ducking Depth control. Mic 1 input shall have ducking priority over Inputs 2 and 3, with dedicated ducking depth control. The unit shall be pre-wired for either 120VAC or 240VAC mains. The unit shall weigh 8.7 lbs (3.95kg), and have dimensions of 11.4”W x 3”H x 7.3”D (290mm x 76mm x 185mm). The unit shall have an optional rack-mounting kit available for standard 19” rack. The unit shall be cCSAus listed for safety. The unit shall be an Ashly TM-335. TM-360 The unit shall be a three input mixer combined with a maximum 60W amplifier using transformer isolated outputs for Low Z (4 Ohm), 25V, or 70V speakers. There shall be a front panel level control for each input, a master level control, and a master bass and treble control. There shall be a second zone output and level control for 1W Low Z speaker and balanced 600 Ohm line output. Input 1 input shall use a Euroblock connector and have a gain control from 0dB to +50dB. Inputs 2 and 3 shall use Euroblock and summed stereo RCA jacks and have gain control from –10dB to +10dB. There shall be an additional front panel 3.5mm TRS jack on Input 2 that overrides the rear panel Input 2. Input 1 shall offer muting priority over Input 2, which shall offer muting priority over Input 3. There shall be switching for Zone 2 Assign, Vox Trigger, Mute Link 2&3, Low Cut Filter, and Input 1 phantom power for microphone. There shall be a front panel power switch, and a standby mode triggered by audio inactivity or contact closure. The unit shall be pre-wired for either 120VAC or 230VAC mains, and draw less than 24W. The unit shall weigh 7 lbs (3kg), and have dimensions of 11.8”W x 2”H x 9.02”D (300mm x 51mm x 230mm). The unit shall have an optional rack-mounting kit available for standard 19” rack. The unit shall be an Ashly TM-360.