Ashly mXa-1502 AquaControl Firmware Revision History ---------------------------------------------------- NOTE: units with firmware lower than version 1.1.6 must be updated to 1.1.6 first before proceeding to the latest version. Version 1.2.28 (Service Release) 01-25-2024  - Fix bug with unintended link group updates and subpreset recall.  - Fix Leading Zero bug where events page would not draw.  - Fixed issue with some multiparameter WR5 controls not working (Add Dynamic remote permissions).  - Fixed issue with user losing remote permissions when exported settings are imported.  - Fixed issue with import options not working correctly.  - Fixed automix meters scaling improperly and indexing which was off by 1.  - Fixed FIR to allow all file types as stated in UI. Fixed prepopulated filter in fir file selection. Fixed issue with parser for fir file.  - Fixed issue where compressor attenuation bus did not work.  - Improved automixer detector.  - Fixed autoleveler target level too high by +3dB due to peak vs avg detection.  - Fixed autoleveler gain decrease rate which used to affect both incr and decr rates.  - Fixed gate threshold too high by +3dB due to peak vs avg detection.  - Fixed level mismatch of signal generator's white and pink signals.  - Fixed ambient noise compensation input noise signal level 3dB too low. Version 1.2.25 (Service Release) 02-06-2023  - Fixed issue where admin account password is reset to the factory default on cold boot.  - Fixed bug with Presets not saving DSP block functions that was introduced in v1.2.22 release.  - Fixed issue with detecting/resetting invalid Real Time Clock parameters. Version 1.2.22 (Service Release) 10-24-2022  - Added Ducker improvement so channels that are not routed or muted at the mixer no longer affect ducking.  - Fixed issues with subpreset recall related to output mutes, mixer assignments and other settings that could cause the process to hang or not execute properly.  - Fixed Virtual WR-5 Level fader's Mixer Input Gain feature to allow it to control multiple selected mixers.  - Fixed a networking issue that caused a redundant DHCP IP assignment when Manual Configuration (Static IP) is selected.  - Fixed issue where Ethernet shuts off until reboot when Network Configuration is changed from Manual Configuration (Static IP) to Automatic Configuration (DHCP).  - Fixed issue where the first login to AquaControl results in an immediate logout. Version 1.2.19 (Service Release) 04-06-2022  - Added a fix for invalid date & time values, which may occur when power is removed and the clock backup battery is dead.  - Fixed an issue that could erroneously log low battery faults on power up with a good clock backup battery installed.  - Fixed issue where meters stop working when firmware update fails due to an invalid firmware file until power is interrupted to the unit. Version 1.2.17 (Service Release) 02-17-2022  - Fixed issue that prevented link-local IP assignment and discovery from working with some PC OS versions.  - Improved firmware update to significantly reduce the duration of the process and its memory usage.  - Improved firmware update so file validation won't fail if the system date/time is older than the firmware file encryption date.  - Updated backend communications to improve performance, especially when lots of DSP functions with meters are populated.  - Fixed issue where the GEQ and PEQ graphs did not refresh after selecting the flatten button.  - Fixed issue where compressor/limiter attenuation LEDs would all light when in bypass.  - Fixed issue where a Virtual WR5 remote would show a blank screen if an unpopulated meter is assigned.  - Fixed issue where last recalled preset name was not being changed by scheduled or triggered preset recalls.  - Fixed cache clearing issue that could cause errors on some AquaControl pages after a firmware update.  - Fixed issue where the AutoLeveler Gain meter LEDs would turn off when the gain reduction surpassed the lowest LED threshold. Version 1.2.8 (Service Release) 10-04-2021  - Fixed bug introduced in v1.2.7 that blocked events from executing.  - Fixed issue that inhibited meter activity on Compare Meters page.  - Fixed issue that caused Security page cropping on some displays. Version 1.2.7 (Service Release) 09-22-2021 NOTE: this update may take up to 16 minutes to complete. Future updates will execute much quicker due to changes in this release.  - Increased memory space to prevent loss of audio and other functional issues after long periods of continuous operation.  - Revamped meters and other periodic processes to improve system performance.  - Fixed an issue that blocked trigger status updates on AquaControl->Settings->Rear Panel page.  - Disabled a redundant DHCP service that was requesting a second IP address, even when set to static IP.  - Revamped firmware update to speed up the process for future updates.  - Updated RTC settings to reduce current draw. Version 1.2.5 (AquaControl Portal Initial Release) 08-26-2021  - Added diagnostic log entries when import, export, and preset/sub-preset recall occur.  - Updated sleep time limit to 120 minutes and allowed it to be editable even when Sleep is off.  - Added software factory reset in AquaControl general settings for Admin users. (In AquaControl Portal only.) Version 1.2.4 (Service Release) 07-20-2021  - Fixed an issue that may cause meters and duckers to stop working after several weeks of continuous operation.  - Fixed critical bug that may lock the power state off when certain reset or power toggle sequences occur.  - Restored SimpleControl API permission that was inadvertently blocked in v1.2.0 release.  - Fixed bug introduced in v1.2.2 that blocked status information on Front Panel and Rear Panel pages.  - Fixed bug introduced in v1.2.0 release that blocked the ability to edit usernames and passwords.  - Added database health check on bootup to make sure factory reset completed successfully before power was removed.  - Added pop-up notifications when preset recall and import are completed.  - Added quality improvements to event and virtual WR-5 creation to provide tips/warnings when necessary fields are empty. Version 1.2.2 (Virtual WR-5 Public Release) 05-14-2021  - Added Virtual WR-5 remote and remotes management page improvements from beta test review.  - Added the ability to save/load individual presets to/from files on client device.  - Added the ability to save/load individual templates to/from files on client device.  - Fixed issue with level control faders where incremental changes were not being sent as the fader is held and moved.  - Fixed problem where special characters and trailing spaces in names could prohibit access to presets, templates, and import data.  - Fixed issue where action sequences may appear out of order.  - Improved browser cache management to automatically refresh pages as newer versions are released.  - Removed 2 minute timeout from firmware update file transfer and decryption step. Version 1.2.0 (Virtual WR-5 Beta Release) 03-10-2021  - Added Virtual WR-5 remote and remotes management pages. Version 1.1.8 (Ducker Enhancements) 02-03-2021  - Added hold time parameter to each ducker channel.  - Added bypass option to each ducker channel.  - Changed ducker depth and release rate so they're now determined by the trigger channel.  - Reduced ducker infinite depth step-off from -60dB to -100dB. Version 1.1.6 (Service Release) 12-14-2020  - Fixed issue that caused firmware update to occasionally fail to execute.  - Fixed issue that causes audible pop when cycling power with Phantom Power engaged.  - Improved Ducker release transition from infinite depth.   - Fixed issue where templates may not load correctly if the signal chain isn't cleared.  - Fixed issue where renaming templates isn't reflected until you refresh the page.  - Updated diagnostics to show all low RTC battery logs regardless of selected date range. Version 1.1.5 (Internal Test Release of V.WR-5 remote) 12-10-2020  - Alpha release of Virtual WR-5 custom remote and remotes management pages. Version 1.1.4 (New Feature Release) 10-23-2020  - Added "simplecontrol" HTTP APIs, to simplify access via 3rd-party control systems.  Version 1.1.2 (Service Release) 10-08-2020  - Fixed issue that caused Link-local discovery to stop working after DHCP IP assignment.  - Fixed issue where odd-order HPFs inverted signal polarity.  - Fixed issue where amp bridging status was not updated to the DSP after power cycle.  - Fixed issue where mic preamp gain was not restored correctly after importing settings from a file. Version 1.1.1 (New Feature Release) 09-24-2020  - New feature: input and output DSP signal chain templates.  - New feature: added 1st, 5th, 6th, and 7th-order Butterworth, Bessel, and Linkwitz-Riley crossover, HPF, and LPF filter types.  - New feature: Link Group implementation is completed for all applicable DSP functions.  - Updated date picker for compatibility with more browsers.  - Added non-supported browser warning to login screen.  - Added warning to Import Settings to inform what settings will be overwritten.  - Fixed issue where AquaControl may sometimes go offline temporarily when cycling power with the front panel power button.  - Fixed issue that may cause the amplifier outputs to stay muted after reboot or power cycle.  - Fixed issue that causes occasional, self-recovering DSP boot failures.  - Fixed issue where a diagnostic meter response fault message may be logged after power is turned off.  - Fixed Mixer Remote Mic In 1 meter so it now shows the level at the input of the mixer. Version 1.0.28 (Internal Test Release) 08-27-2020  - Added input and output DSP chain template save/load feature.  - Added 1st, 5th, 6th, and 7th order filter types to crossovers, HPF, and LPF.  - Added link group feature implementation to DSP functions.  - Fixed Butterworth 48dB/octave HPF response.  - Fixed FIR filter coefficient processing order.  - Improved firmware update, so it won't hang if there are any network errors.  - Fixed bug where GEQ settings are not restored on power up. Version 1.0.27 (Service Release) 7-30-2020  - Added the ability to overwrite presets and subpresets during save process.  - Fixed clock change issue that may cause VCAs and ducker to stop working.  - Made signal generator frequency fader logarithmic.  - Corrected gate threshold units to dBu.  - Added internet NTP servers for automatic date/time to use if local network NTP is not available.  - Fixed bug where AquaControl may display the date setting of the client computer instead of the mXa.  - Added RTC battery check and diagnostic log warning when battery is missing or low.  - Fixed "Forbidden" errors on pages when accessed by Operator role.  - Fixed meter and ducking latency when multiple metered items are populated.  - Fixed issue where network settings were not updating, and diagnostics IP logs occurred every time network settings page is refreshed.  - Fixed problems with preset recall and import settings when Butterworth 18dB/octave filter type is used.  - Added username and password maximum length warnings.  - Fixed issue that may cause presets to be lost after firmware update or system restart.  - Removed number sign (#) from the beginning of the Last Recalled Preset name. Version 1.0.24 (Service Release) 5-28-2020  - Fixed a bug that prevented the event scheduler from working.  - Fixed issue where DCA groups did not remember their names.  - Improved VCA response time. Version 1.0.23 (Service Release) 05-20-2020  - Fixed bug where recalling a re-named preset may cause the server to disconnect. Version 1.0.22 (Service Release) 05-12-2020  - Fixed bug where DCA causes mute states, meters, and mixer selections to stop working after cold-boot. Version 1.0.21 (Service Release) 05-08-2020  - Made changes to network discovery, for compatibility with different versions of Windows.  - Improved firmware update process.  - Fixed phantom power and mic preamp muting bug.  - Fixed bug where export/import can corrupt preset parameters.  - Fixed 2-state trigger actions so they revert on open transition.  - Fixed auto-leveler input meter scaling.  - Fixed VCA net level reporting.  - Added more level markers and labels to meters.  - Corrected limiter and compressor threshold units to dBu.  - Improved accuracy of power plug value.  - Added DSP overflow prevention to subpreset recall, copy/paste, and block add.  - Updated error messages to make their text more meaningful.  - Removed inapplicable advanced settings from network page. Version 1.0.20 (Service Release) 04-10-2020  - Updated DHCP and Link-local discovery for compatibility with recent Windows 10 updates.  - Added international time zones to system clock settings. Version 1.0.19 (Production Release) 03-27-2020  - Completed remaining DSP functions.  - Added features and improvements based on Beta and Pilot production feedback.  - Updated factory and admin reset to set networking to automatic (DHCP). Version 1.0.08 (Pilot Release) 12-18-2019