Q-SYS plugin for Ashly Protea Amplifiers

The Ashly Q-SYS Plugin allows control and monitoring of supported amplifiers from Q-SYS Products and Software. Examples of supported functions include: amplifier status, firmware, current preset, input & output meter, channel temperature, etc. For more information please refer to the help documentation linked below.

Ashly amplifier models supported by this plugin are:
pêma4125, pêma4250, pêma8125, pêma8250, ne4250, ne4250pe, ne8250, ne8250pe, nXe752, nXe1502, nXe4002, nXe8002, nXe1.52, nXe3.02, nXe754, nXe1504, nXe4004, nXe8004, nXe1.54, nXe3.04

Please note: this plugin is currently in beta.
If you encounter any issues or would like to provide feedback, please reference the help documentation below, or contact the Ashly Service Department by clicking here and select “Technical Support” before submitting.

Use this plugin to connect to and control network-enabled Ashly Amplifiers.

The plugin is compatible with Q-SYS Designer version 9.4 and above.

NOTE: Visit the Power Amps page for product information and documentation.

Prerequisites

Before you can configure the plugin, the amplifier(s) must be connected to a network and have a valid IP address in a subnet which the Q-SYS core can
communicate with.

The IP address can be obtained or configured from the Ashly amplifier using Ashly Protea NE software, see Protēa™ software suite product page.

It is recommended to configure a static IP address for the amplifier, as DHCP addresses can change.

You will also need to obtain the amplifier MAC address as well as the Username and Password of a local user with “Full Access” access level on the amplifier (default username: admin | default password: *none*).

NOTE: If you are able to connect and monitor the amplifier but are unable to change any control states from within the Plugin,
verify the user credentials and access level.

Configuration Overview

  1. Drag the plugin into your schematic.
  2. In the Plugin Properties pane, select the correct amplifier model.
  3. Press F5 to save your design to the Core and run it. (Or, press F6 to emulate your design.)
  4. In your schematic, double-click the plugin to open the component’s control panel.
  5. In the NETWORK CONFIG section, enter the amplifier IP Address, MAC Address, Username, and Password in their respective fields.

Properties

Name

Type

Default / Range

Model Enum pêma4125, pêma4250, pêma8125, pêma8250, ne4250, ne4250pe, ne8250, ne8250pe, nXe752, nXe1502, nXe4002, nXe8002, nXe1.52, nXe3.02, nXe754, nXe1504, nXe4004, nXe8004, nXe1.54, nXe3.04

Controls

In this Table: n represents the number of input/output channels (1-8)

Tab

Section(s)

Control Name

Control Type

Function

Range

No Conditions
Connection Network Config Status Status Indicator Network status of the amplifier. String
Connection Network Config IP Address Text Enter the amplifier’s IP address. String
Connection Network Config MAC Address Text Enter the amplifier’s MAC address. String
Connection Network Config Username Text Enter local Username created on the amplifier. String
Connection Network Config Password Text Enter local user’s Password (or leave blank, if none) created on the amplifier. String
Connection Amplifier Status OK LED/FAULT LED LED Indicator Shows fault status of amplifier. True, False
Connection Amplifier Status Power Toggle Button Sets on/standby power state. True, False
Connection Amplifier Status Device Name Text Shows the configured name of the amplifier. String
Connection Amplifier Status Device Type Text Shows the model series of the amplifier. String
Connection Amplifier Status Device Firmware Text Shows the current running firmware of the amplifier. String
Presets Presets Preset Name Text Shows the name of a configured preset on the amplifier. String
Presets Presets Preset Load Trigger Button Loads the corresponding preset. N/A
Condition: When selected model has integrated DSP
DSP Inputs DSP Inputs Input 1-n Meter Level Meter Shows the current decibel level on an input channel. -60 – 20 dBu
DSP Inputs DSP Inputs Input 1-n Signal LED Indicator Shows signal detection (above -60dBu) on an input channel. True, False
DSP Inputs DSP Inputs Input 1-n Clipping LED Indicator Shows clipping state of a signal on an input channel. True, False
DSP Inputs DSP Inputs Input 1-n Gain Integer Knob

Sets the gain of an input channel.

Note: Changing the gain of an input channel requires that
respective channel
to have a Gain block manually added to the signal flow
using the Protea NE software.

-50 – 12 dB
DSP Inputs DSP Inputs Input 1-n Mute Toggle Button Sets the mute state of an input channel. True, False
DSP Inputs DSP Inputs Input 1-n Name Text Shows/Sets the name of an input channel. String
DSP Outputs DSP Outputs Output 1-n Meter Level Meter Shows the current decibel level on an output channel. -60 – 20 dBu
DSP Outputs DSP Outputs Output 1-n Signal LED Indicator Shows signal detection (above -60dBu) on an output channel. True, False
DSP Outputs DSP Outputs Output 1-n Clipping LED Indicator Shows clipping state of a signal on an output channel. True, False
DSP Outputs DSP Outputs Output 1-n Protect LED Indicator Shows protect state of a signal on an output channel. True, False
DSP Outputs DSP Outputs Output 1-n Gain Integer Knob

Sets the gain of an output channel.

Note: Changing the gain of an output channel requires that
respective channel
to have a Gain block manually added to the signal flow
using the Protea NE software.

-50 – 12 dB
DSP Outputs DSP Outputs Output 1-n Mute Toggle Button Sets the mute state of an output channel. True, False
DSP Outputs DSP Outputs Output 1-n Temperature Text Shows the temperature of an output channel. String
DSP Outputs DSP Outputs Output 1-n Name Text Shows/Sets the name of an output channel. String
Condition: When selected model does not have integrated DSP
Control Channels Input 1-n Meter Level Meter Shows the current decibel level on an input channel. -20 – 20 dBu
Control Channels Output 1-n Meter Level Meter Shows the current decibel level (down from clip) on an output channel. -40 – 0 dB
Control Channels Input 1-n Signal LED Indicator Shows signal detection (above -20dBu) on an input channel. True, False
Control Channels Output 1-n Clipping LED Indicator Shows clipping state of a signal on an output channel. True, False
Control Channels Output 1-n Protect LED Indicator Shows protect state of a signal on an output channel. True, False
Control Channels Output 1-n Mute Toggle Button Sets the mute state of an output channel. True, False
Control Channels Output 1-n Temperature Text Shows the temperature of an output channel. String
Control Channels Output 1-n Name Text Shows/Sets the name of an output channel. String

CONTACT