Q-SYS plugin for Ashly Protea Amplifiers

The Ashly Q-SYS Plugin allows control and monitoring of supported amplifiers from Q-SYS Products and Software. Examples of supported functions include: amplifier status, firmware, current preset, input & output meter, channel temperature, etc. For more information please refer to the help documentation linked below.

Ashly amplifier models supported by this plugin are:
pêma4125, pêma4250, pêma8125, pêma8250, ne4250, ne4250pe, ne8250, ne8250pe, nXe752, nXe1502, nXe4002, nXe8002, nXe1.52, nXe3.02, nXe754, nXe1504, nXe4004, nXe8004, nXe1.54, nXe3.04, nXp752, nXp1502, nXp4002, nXp8002, nXp1.52, nXp3.02, nXp754, nXp1504, nXp4004, nXp8004, nXp1.54, nXp3.04

Please note: this plugin is currently in beta.
If you encounter any issues or would like to provide feedback, please reference the help documentation below, or contact the Ashly Service Department by clicking here and select “Technical Support” before submitting.

Use this plugin to connect to and control network-enabled Ashly Amplifiers.

The plugin is compatible with Q-SYS Designer version 9.4 and above.

NOTE:  See the Ashly Power Amps product page on the Ashly website for product information and documentation.

Prerequisites

Before you can configure the plugin, the amplifier(s) must be connected to a network and have a valid IP address in a subnet which the Q-SYS core can communicate with.

The IP address can be obtained or configured from the Ashly amplifier using Ashly Protea NE software, see Protēa™ software suite product page.

It is recommended to configure a static IP address for the amplifier, as DHCP addresses can change.

You will also need to obtain the amplifier MAC address as well as the Username and Password of a local user with “Full Access” access level on the amplifier (default username: admin | default password: *none*).
NOTE: If you are able to connect and monitor the amplifier but are unable to change any control states from within the Plugin, verify the user credentials and access level.

Configuration Overview

  1. Drag the plugin into your schematic.
  2. In the Plugin Properties pane, select the correct amplifier model.
  3. Press F5 to save your design to the Core and run it. (Or, press F6 to emulate your design.)
  4. In your schematic, double-click the plugin to open the component’s control panel.
  5. In the NETWORK CONFIG section, enter the amplifier IP Address, MAC Address, Username, and Password in their respective fields.

Properties

 Name

Type

Default / Range

Model

Enum

pêma4125, pêma4250, pêma8125, pêma8250, ne4250, ne4250pe, ne8250, ne8250pe, nXe752, nXe1502, nXe4002, nXe8002, nXe1.52, nXe3.02, nXe754, nXe1504, nXe4004, nXe8004, nXe1.54, nXe3.04, nXp752, nXp1502, nXp4002, nXp8002, nXp1.52, nXp3.02, nXp754, nXp1504, nXp4004, nXp8004, nXp1.54, nXp3.04

Controls

In this Table:
n represents the number of input/output channels (1-8)

Tab

Section(s)

Control Name

Control Type

Function

Range

No Conditions

Connection

Network Config

Status

Status Indicator

Network status of the amplifier.

String

Connection

Network Config

IP Address

Text

Enter the amplifier’s IP address.

String

Connection

Network Config

MAC Address

Text

Enter the amplifier’s MAC address.

String

Connection

Network Config

Username

Text

Enter local Username created on the amplifier.

String

Connection

Network Config

Password

Text

Enter local user’s Password (or leave blank, if none) created on the amplifier.

String

Connection

Amplifier Status

OK LED/FAULT LED

LED Indicator

Shows fault status of amplifier.

True, False

Connection

Amplifier Status

Power

Toggle Button

Sets on/standby power state.

True, False

Connection

Amplifier Status

Device Name

Text

Shows the configured name of the amplifier.

String

Connection

Amplifier Status

Device Type

Text

Shows the model series of the amplifier.

String

Connection

Amplifier Status

Device Firmware

Text

Shows the current running firmware of the amplifier.

String

Presets

Presets

Preset Name

Text

Shows the name of a configured preset on the amplifier.

String

Presets

Presets

Preset Load

Trigger Button

Loads the corresponding preset.

N/A

Condition: When selected model has integrated DSP

DSP Inputs

DSP Inputs

Input 1-n Meter

Level Meter

Shows the current decibel level on an input channel.

-60 – 20 dBu

DSP Inputs

DSP Inputs

Input 1-n Signal

LED Indicator

Shows signal detection (above -60dBu) on an input channel.

True, False

DSP Inputs

DSP Inputs

Input 1-n Clipping

LED Indicator

Shows clipping state of a signal on an input channel.

True, False

DSP Inputs

DSP Inputs

Input 1-n Gain

Integer Knob

Sets the gain of an input channel.

Note: Changing the gain of an input channel requires that respective channel
to have a Gain block manually added to the signal flow using the Protea NE software.

-50 – 12 dB

DSP Inputs

DSP Inputs

Input 1-n Mute

Toggle Button

Sets the mute state of an input channel.

True, False

DSP Inputs

DSP Inputs

Input 1-n Name

Text

Shows/Sets the name of an input channel.

String

DSP Outputs

DSP Outputs

Output 1-n Meter

Level Meter

Shows the current decibel level on an output channel.

-60 – 20 dBu

DSP Outputs

DSP Outputs

Output 1-n Signal

LED Indicator

Shows signal detection (above -60dBu) on an output channel.

True, False

DSP Outputs

DSP Outputs

Output 1-n Clipping

LED Indicator

Shows clipping state of a signal on an output channel.

True, False

DSP Outputs

DSP Outputs

Output 1-n Protect

LED Indicator

Shows protect state of a signal on an output channel.

True, False

DSP Outputs

DSP Outputs

Output 1-n Gain

Integer Knob

Sets the gain of an output channel.

Note: Changing the gain of an output channel requires that respective channel
to have a Gain block manually added to the signal flow using the Protea NE software.

-50 – 12 dB

DSP Outputs

DSP Outputs

Output 1-n Mute

Toggle Button

Sets the mute state of an output channel.

True, False

DSP Outputs

DSP Outputs

Output 1-n Temperature

Text

Shows the temperature of an output channel.

String

DSP Outputs

DSP Outputs

Output 1-n Name

Text

Shows/Sets the name of an output channel.

String

Condition: When selected model does not have integrated DSP

Control

Channels

Input 1-n Meter

Level Meter

Shows the current decibel level on an input channel.

-20 – 20 dBu

Control

Channels

Output 1-n Meter

Level Meter

Shows the current decibel level (down from clip) on an output channel.

-40 – 0 dB

Control

Channels

Input 1-n Signal

LED Indicator

Shows signal detection (above -20dBu) on an input channel.

True, False

Control

Channels

Output 1-n Clipping

LED Indicator

Shows clipping state of a signal on an output channel.

True, False

Control

Channels

Output 1-n Protect

LED Indicator

Shows protect state of a signal on an output channel.

True, False

Control

Channels

Output 1-n Mute

Toggle Button

Sets the mute state of an output channel.

True, False

Control

Channels

Output 1-n Temperature

Text

Shows the temperature of an output channel.

String

Control

Channels

Output 1-n Name

Text

Shows/Sets the name of an output channel.

String